Aka Liquid Resistance Starter

Home / Aka Liquid Resistance Starter

  • Liquid starter : Liquid rheostat Electrolytic Starter

    AKA SOLUTIONS FOR CEMENT PLANT & MINES . Robust, simple and reliable. Stepless thanks to a continuous variation of the resistance. Easy to adapt to different motor. Cost effective. Low maintenance costs (minimizes shocks, and energy usage)

  • AKEP : liquid rotor starter Aka Automatismes

    AKA liquid resistance starter. AKEP liquid rheostat. Home > Liquid starters > AKEP for Cement Plant. AKEP : Liquid resistance starter for slip ring motors. Range ; Starting Characteristics Ambient temperature AK10EP AK15EP AK25EP AK45EP; Starting Torque= 120%. Starting Time = 20sec. 40°C 1250 KW 3000 KW 5000 KW 10000 KW; Starting Torque= 120%. Starting Time = 30sec 40°C 1100

  • What is a liquid resistance starter? Quora

    2018-03-14· It is an electrical device by which the starting current of very large electrical motors is controlled by using, in series with the motor-winding, a resistance consisting of an electrolytic bath through which current has to flow. By using movable

  • What is rotor resistance starter?2018-09-09How does a liquid starter opperate?2016-06-16See more results
  • Liquid Resistance Starter YouTube

    2018-01-08· How to measure your liquid starter resistance ? Duration: 4:21. Electrical Engineering 9,568 views. 4:21. Turn a ceiling fan into a wind turbine generator?! Duration: 14:42.

  • Author: RUPESH USADADIYA
  • How a liquid resistance starter works Answers

    2011-03-28· Combination of water and caustic soda for improving the resistance in starter, that's called Liquid Resistance. starter. If any slip ring Induction motor, at the time of starting

  • Liquid resistor Wikipedia

    A liquid resistor is an electrical resistor in which the resistive element is a liquid. Fixed-value liquid resistors are typically used where very high power dissipation is required. They are used in the rotor circuits of large slip ring induction motors to control starting current, torque and to limit large electrical fault currents (while other protection systems operate to clear or isolate

  • Induction Motor Starting Methods Brighthub Engineering

    This starter is used with a wound rotor induction motor. It uses an external resistance/phase in the rotor circuit so that rotor will develop a high value of torque. High torque is produced at low speeds, when the external resistance is at its higher value.

  • Liquid resistor Wikipedia

    A liquid resistor is an electrical resistor in which the resistive element is a liquid. Fixed-value liquid resistors are typically used where very high power dissipation is required. They are used in the rotor circuits of large slip ring induction motors to control starting current, torque and to limit large electrical fault currents (while other protection systems operate to clear or isolate

  • Liquid Resistance Starter YouTube

    2018-01-08· How to measure your liquid starter resistance ? Duration: 4:21. Electrical Engineering 9,568 views. 4:21. Turn a ceiling fan into a wind turbine generator?! Duration: 14:42.

  • Author: RUPESH USADADIYA
  • How a liquid resistance starter works Answers

    2011-03-28· Combination of water and caustic soda for improving the resistance in starter, that's called Liquid Resistance. starter. If any slip ring Induction motor, at the time of starting

  • What is the major difference between soft starter and

    The liquid starter has movable plates rather than relieing on heating to change the resistance. When starting the motor the operator monitors the stator current and manually controls the starter, keeping the stator current just below the motor protection pick up point.

  • What is a liquid resistance starter?where it is used??

    resistance in starter, i.e. called Liquid Resistance starter. If any slip ring Induction motor, at the time of starting given the external resistance required to rotor side, why because starting current and startying torque is very high. So we are using resitance starter.Depend on motor capacity,at that place using Liquid resistance starter.

  • Rotor Resistance Starter ~ your electrical home

    The calculation of steps of rotor resistance starter is based on the assumptions that, 1. The motor starts against a constant torque. 2. The rotor current fluctuates between two fixed values, a maximum and a minimum, denoted as I 2max and I 2min. The Fig. 2, shows a single phase of a three phase of a three phase rheostat to be inserted in the rotor. The starter has n steps,

  • Liquid resistance starter (LRS) or electrolytic starter by

    Electrolytic starters for slipring motors The electrolytic starter, also named Liquid Resistance Starter (LRS) or rotor starter, supplies the slipring machine the power necessary to drive it by resistance variation.

  • How to measure your liquid starter resistance ? YouTube

    2016-09-07· how to repair replace broken circuit breaker multiple Electric outlet not working fuse box panel Duration: 5:09. DIY Tinker 751,670 views

  • What is rotor resistance starter? Quora

    2018-09-10· Starter means which limits starting current(major priority) and also it can be used to control the speed of a machine. Rotor resistance starter is used with a wound

  • Induction Motor Starting Methods Brighthub Engineering

    This starter is used with a wound rotor induction motor. It uses an external resistance/phase in the rotor circuit so that rotor will develop a high value of torque. High torque is produced at low speeds, when the external resistance is at its higher value.

  • Stator Resistance Starter ~ your electrical home

    When stator resistance starter is used, the factory by which stator voltage reduces is say x < 1. The starting current is proportional to to this factor x. So if I sc is the normal current drawn under full rated voltage condition at start then,

  • AKEP BROCHURE FOR CEMENT aka-automatismes

    AKA solution AKA developed a robust and reliable range of liquid starters suitable for heavy duty applications such as mines,cementplants,shreddersorconveyors. Since 1990 AKA focused in improving its starter performance so it can meet very specific requirements for

  • LIQUID RESTISTANCE STARTER Electric motors & generators

    2002-06-17· The water volume of the tank is 25 litres.The motor is not matched to the starter both items were obtained independantly, the duty is extreme with the motor starting a large ring mill crusher and no figures are available on the inertia .The crusher is designed to crush 700 tons per hour at 230kw.The Supply Athority has requested that the motor only draw 1.5 times full load on start up.

  • LIQUID RESISTANCE MOTOR STARTERS

    Liquid Resistance provide high starting resistance to rotor circuit, cutting the resistance sleeplessly synchronizing with Motor Acceleration to very low or negligible value near Full Load speed. This gives a high Starting Torque and very smooth start. The above figure shows the comparisons of Grid Resistance Start and Liquid Resistance Start.

  • ARL: liquid rotor starters fixed electrodes Aka Automatismes

    The ARL starter based on Intrinsic characteristics of electrolytes provides a decreasing resistance when current flow. is disabled. Allow the deposit of cookies to access this feature.

  • How is the circuit diagram of liquid resistance starter

    2018-03-14· Usually liquid resistance starters used to start HT induction motors where there is large torque required to deliver at the time of start. Ex- Cement mill etc

  • Liquid Resistance Starter Liquid Resistance Controllers

    Liquid Resistance Starter. These are used for inserting external resistance in the rotor circuit of slip ring induction motor at the starting to reduce starting current and increase starting torque. used in various industries and installations like : cement plants, rolling mills,pumping plants, sugar mills, paper plants. we manufacture & supply liquid rotor resistances with both motor

  • Liquid Resistance Starter Motor Starting LMPForum

    2010-10-11· Liquid Resistance Starter posted in Motor Starting: I am desperately looking for schematics of AKA electrolyte type starter for 1800kW 3.3kV mill motor.Any help, such as mentioned schematics or any info about manufacturer will be appreciated.

  • LIQUID RESISTANCE STARTERS

    Fixed electrode liquid resistance starters m350 sTArTer for use with low and medium voltage wound rotor motors from 200 kW to 750 kW, maximum rotor volts = 1500 V OVerVieW The M350 is a two stage liquid resistance starter, each stage replacing the equivalent of approximately five stages of fixed resistance.

  • Liquid starter Electric motors & generators engineering

    2003-07-31· Hello niallnz In an old motor shop we had a liquid starter that we used to load test our generators.We used a brine solusion in it and controlled the resistance by moving 3 rods in and out of the brine.We didn't have to be very concerned about the Conductivity of the solution,because our primary need was to creat a measurable load.